  • Only Water Enters Your Home, THERMA V Hydrosplit

    LG THERMA V Hydrosplit cuts carbon emissions with great energy saving. It’s simple and safe heat pump with water piping. It connects to indoor unit with separate water tank or just one water tank integrated indoor unit. Contact us for this sustainable heat pump system.
    Illustration of how the product is installed

    A Simple, Safe Heat Pump with Water Piping

    The LG Therma V Hydrosplit reduces the risk of indoor refrigerant leakage by keeping refrigerant safely outside: only water passes through your home. You'll have more utility room space and easy maintenance access thanks to its lightweight, quickly installable wall-mounted unit or floor-standing unit with an integrated water tank. Plus, you don't need to install an additional water tank since the floor standing type indoor unit already includes one.
    Bathroom, indoor unit, outdoor unit, shown from the front

    Keep Your Entire House Warm
    with an Energy-Saving Heat Pump

    The LG Therma V Hydrosplit reduces energy bills with the highest energy efficiency energy label rating of A+++, You also get comfortable, reliable heating performance — especially at low ambient temperature — in a multi-purpose heating solution ranging from space heating to hot water supply. Whether it's -25°C or 35°C, the Hydrosplit offers a stable hot water supply thanks to a wide operation range.
    * Energy Label is based on COMMISSION DELEGATED REGULATION (EU) No 811/2013. LG Therma V R32 Hydrosplit reaches energy label ErP A+++ for space heating 35°C LWT and ErP A++ for space heating 55°C LWT. The results of the energy label may vary depending on the LG Therma V model. Please refer to the LG Compliance Information homepage (http://www.ccc-sh.net/global/support/cedoc/cedoc) for model-specific information.

    **Based on the performance table of the PDB, 100% of Normal Capacity with Outdoor Ambient Temperature -7℃ DB & Leaving Water Temperature 55℃. Capacities on the performance table are in accordance with EN14511 but are simulation values and may differ from actual values. The outdoor temperature range for heating mode is indicated in the operation range of the PDB (Product Data Book). However, in general, compared to normal outdoor temperatures, when the outdoor temperature is lower, the capacity, efficiency, and maximum water outlet temperature at that outdoor temperature will also be lower than norrmal outdoor temperature operation.

    Spec Detail

    The LG air to water heat pump line-up features various models.

    Spec Detail
      R32 Hydrosplit R32 Hydrosplit
    R32 Hydrosplit hydro box, rectangular shape LG Therma V indoor unit with rectangular shape two stacks outdoor unit displayed.
    R32 Hydrosplit IWT, rectangular shape integrated water tank unit with rectangular shape two stacks outdoor unit displayed.
    Features
    R32 Hydrosplit Hydro Box
    R32 Hydrosplit IWT
    Refrigerant & GWP R32 / 675 R32 / 675
    Capacity Range (kW) (1?&3?) 12 / 14 / 16 (1?&3?) 12 / 14 / 16
    Energy Efficiency Class for Heating
    A+++ / A++ (35℃ / 55℃)
    for Heating
    A+++ / A++ (35℃ / 55℃)
    Energy Efficiency Class - for Water Heating
    A+1)
    Power Supply (V, ?, Hz) 220-240, 1, 50
    380-415, 3, 50
    220-240, 1, 50
    380-415, 3, 50
    Dimension, ODU
    (WxHxD,mm)
    950 × 1,380 × 330 950 × 1,380 × 330
    Weight, ODU
    (kg)
    (1?&3?) 91.7 (1?&3?) 91.7
    Dimension, IDU
    (WxHxD,mm)
    490 × 850 × 315 601 × 1,812 × 685
    Weight, IDU
    (kg)
    30.5 130
    Sound Power Level
    ODU (dB(A))
    61 / 62 / 63 61 / 62 / 63
    Sound Power Level
    IDU (dB(A))
    44 43
    Operation Range (OAT, ℃) Heating: -25 ~ 35
    Cooling: 5 ~ 48
    Heating: -25 ~ 35
    Heating: -25 ~ 35
    Operation Range (LWT, ℃) Heating: 15 ~ 65
    Cooling: 5 ~ 27 (16 ~ 27)2)
    Heating: -25 ~ 35
    Cooling: 5 ~ 27 (16 ~ 27)2)
    Operation Range (LWT, ℃) DHW: 15 ~ 803) DHW: 15 ~ 803)
    Model Name
    (ODU, 1?)
    HU121MRB U30
    HU141MRB U30
    HU161MRB U30
    HU121MRB U30
    HU141MRB U30
    HU161MRB U30
    Model Name
    (ODU, 3?)
    HU123MRB U30
    HU143MRB U30
    HU163MRB U30
    HU123MRB U30
    HU143MRB U30
    HU143MRB U30
    Model Name
    (IDU)
    HN1600MC NK1 HN1616Y NB1
    Spec Detail
     
     
    Features
    Refrigerant & GWP
    Capacity Range (kW)
    Energy Efficiency Class
    Energy Efficiency Class
    Power Supply (V, ?, Hz)
    Dimension, ODU
    (WxHxD,mm)
    Weight, ODU
    (kg)
    Dimension, IDU
    (WxHxD,mm)
    Weight, IDU
    (kg)
    Sound Power Level
    ODU (dB(A))
    Sound Power Level
    IDU (dB(A))
    Operation Range (OAT, ℃)
    Operation Range (LWT, ℃)
    Operation Range (LWT, ℃)
    Model Name
    (ODU, 1?)
    Model Name
    (ODU, 3?)
    Model Name
    (IDU)
    Spec Detail
    R32 Hydrosplit R32 Hydrosplit
    R32 Hydrosplit hydro box, rectangular shape LG Therma V indoor unit with rectangular shape two stacks outdoor unit displayed.
    R32 Hydrosplit IWT, rectangular shape integrated water tank unit with rectangular shape two stacks outdoor unit displayed.
    R32 Hydrosplit Hydro Box
    R32 Hydrosplit IWT
    R32 / 675 R32 / 675
    (1?&3?) 12 / 14 / 16 (1?&3?) 12 / 14 / 16
    for Heating
    A+++ / A++ (35℃ / 55℃)
    for Heating
    A+++ / A++ (35℃ / 55℃)
    - for Water Heating
    A+1)
    220-240, 1, 50
    380-415, 3, 50
    220-240, 1, 50
    380-415, 3, 50
    950 × 1,380 × 330 950 × 1,380 × 330
    (1?&3?) 91.7 (1?&3?) 91.7
    490 × 850 × 315 601 × 1,812 × 685
    30.5 130
    61 / 62 / 63 61 / 62 / 63
    44 43
    Heating: -25 ~ 35
    Cooling: 5 ~ 48
    Heating: -25 ~ 35
    Heating: -25 ~ 35
    Heating: 15 ~ 65
    Cooling: 5 ~ 27 (16 ~ 27)2)
    Heating: -25 ~ 35
    Cooling: 5 ~ 27 (16 ~ 27)2)
    DHW: 15 ~ 803) DHW: 15 ~ 803)
    HU121MRB U30
    HU141MRB U30
    HU161MRB U30
    HU121MRB U30
    HU141MRB U30
    HU161MRB U30
    HU123MRB U30
    HU143MRB U30
    HU163MRB U30
    HU123MRB U30
    HU143MRB U30
    HU143MRB U30
    HN1600MC NK1 HN1616Y NB1
    1) 5.5, 7 & 9kW : profile L
    2) When fan coil unit is not used.
    3) DHW 58 ~ 80°C operating is available only when the electric heater is operating.
    *ODU : Outdoor Unit, IDU : Indoor Unit
    **OAT : Outdoor Air Temperature, LWT : Leaving Water Temperature

    Heat Pump FAQs

    We know that you want to ask about the Heat Pump. Please click the link below for more information.

    Related Products

    • Product Image

      Split

      ? Flexible installation
      ? Heating, cooling and hot water supply
      ? A+++ energy class (average climate at 35℃ water outlet)
      ? Leaving water temperature up to 65 ℃ for R32 / 57 ℃ for R410A / 80℃ for High temperature
      ? Works at outdoor temperature as low as -25 ℃
      ? Outdoor unit connects to indoor unit by refrigerant piping
      ? Free of potential freezing risk
      ? Wall-mounted hydro box or floor-standing integrated water tank type indoor unit

    • Product Image

      Monobloc

      ? Simple all-in-one solution
      ? Heating, cooling and hot water supply
      ? A+++ energy class (average climate at 35℃ water outlet)
      ? Leaving water temperature up to 65 ℃
      ? Works at outdoor temperature as low as -25 ℃
      ? No indoor space for indoor unit needed
      ? Safe indoor environment from leaking refrigerant.